Rust Ring Remover Alger brush Motor tungsten Burrs Titanium Handpiece Massage polishing device
Specification 1. Battery Operated Single speed motorized handpiece. Tip cover, work with"AA"BURS and burrs (BATTERY NOT includes ) 2.Burr size :0.5mm,1.0mm,3.5mm 3.A complete set of a power handle and a tungsten burr, overall length 105mm Note: The Burrs can be offered separately , please contact us for more information Operation
- To start the AlgerBrush ,turn end nut in "ON", direction indicated to the right
- To stop the AlgerBrush, turn end nut in "OFF", direction indicated to the left
Note: to ensure the AlgerBrush is "OFF" ,check that the chuck and burr have stopped spinning.
Installation/Changing of Battery
Note: when changing battery ,care should be taken not to put pressure on the battery clip as it may break at the point where it attaches to the motor
- Remove chuch and bur assembly
- Remove end nut
- Slide motor and battery assembly out of housing
- Battery must be installed. -Pole first (if battery installed +Pole first, the bursh will not fuction properly)
- Place new battery between motor and battery clip (-Pole next to motor)
- Re-insert motor and battery assemby into hoursing
- Ensure mtor seated properly in hoursing by checking the following
- Motor shaft centered in hole at tip of housing
- Tip of motor shaft just even with top of housing
- Partially tighten end nut
Installation of Chuck and burrs assembly
Note: Motor must be spinning when installing chuck and burr assembly to ensure motor seated properly
- To install , ensure motor is spinning ,i.e., AlgerBrush is "ON"
- Gently push chuck and burr assembly oto motor shaft
- Base of Chuck should be close to ,but not touching ,top of house
- Turn"off" AlgerBrush until read to use
- Grasp base of chuck with fingers and pull away from motor shaft- or-
- Gently prychuck off motor shaft with suitable instrument
- Turn"OFF"AlgerBrush until read to use
- Remove chuck and burr assembly from motor shaft
- While Grasping base of chuch with fingers ,grasp shaft of bur with foley hemostat and pull apart
- To insert new "sterilized"burr ,use foley hemostat to grasp burr (grasp in middle of shaft),then push chuck on to botton of burr shaft until snug.
Note: Burrs fits into "longer" end of chuck.
|
|
|
|
|